Luminaires - Part 1: General requirements and tests
< !-- NEW! --> IEC 60598-1:2020 is available as < a href=" https:/ / webstore.iec.ch/ publication/ 67473" > IEC 60598-1:2020 RLV< / a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.< / br> < / br> IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0 - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984 - Addition of Subclause 3.3.25, UV protection of cable - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493) - Revision of the requirements for functional earth and protective earth - Addition of Clause 4.35, Protection against fast rotating parts - Revision of Clause 3.2, Rated voltage marking - Revision of Subclause 5.2.10, Cord anchorage - Revision of Annex G for touch current and protective conductor current test set-up - Addition of requirements for constant light output function and programmable current output - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage - Introduction of PELV - Introduction of Ethernet power supply connection for luminaires (PoE) - Section 9, Introduction of IPX9 - Addition of Subclause 3.3.26 for wall mounted luminaires - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/ AMD2:2019 - Revision of Subclause 10.2.2, alternative DC electric strength test - Revision of Annex D for recessed luminaires - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands - Revision of use of bridging capacitors in luminaires - Revision of electrical connection to class III plugs.< ol style=" list-style-type:lower-alpha" >
View in