Eurocode 3 - Design of steel structures - Part 1-5: Plated structural elements
1.1 Scope of EN 1993-1-5 (1) This document provides rules for structural design of stiffened and unstiffened nominally flat plates which are subject to in-plane forces. (2) Non-uniform stress distributions due to shear lag, in-plane load introduction and plate buckling are covered. The effects of out-of-plane loading are outside the scope of this document. NOTE 1 The rules in this part complement the rules for class 1, 2, 3 and 4 sections, see EN 1993-1-1. NOTE 2 For the design of slender plates which are subject to repeated direct stress and/ or shear and also fatigue due to out-of-plane bending of plate elements (" breathing" ), see EN 1993-2 and EN 1993-6. NOTE 3 For the effects of out-of-plane loading and for the combination of in-plane effects and out-of-plane loading effects, see EN 1993-2 and EN 1993-1-7. (3) Single plate elements are considered as nominally flat where the curvature radius r in the direction perpendicular to the compression satisfies, as illustrated in Figure 1.1: r≥b^2/ t (1.1) where b is the panel width t is the plate thickness. Figure 1.1 - Definition of plate curvature 1.2 Assumptions (1) Unless specifically stated, EN 1990, the EN 1991 series and EN 1993-1-1 apply. (2) The design methods given in EN 1993-1-5 are applicable if \- the execution quality is as specified in EN 1090-2 and \- the construction materials and products used are as specified in the relevant parts of the EN 1993 series or in the relevant material product specifications.