Safety rules for the construction and installation of lifts - Lifts for the transport of persons and goods - Part 21: New passenger and goods passenger lifts in existing building
This document specifies the safety rules related to passenger and goods/ passenger lifts installed in existing buildings where limitations enforced by certain building constraints mean that some requirements of EN 81-20:2020 cannot be met.It addresses the following constraints and gives requirements for alternative solutions: - existing perforate walls of the lift well - reduction in available well are leading to reduced distance between car, counterweight or balancing weight - counterweight or balancing weight in a separate existing well - reduced building dimensions and clearances leading to:- reductions in available space for headroom and pit - reduced car roof balustrade dimensions - reduced height of sill apron - reduced height of machine and/ or pulley room - reduced available area for access door/ trap door - reduction in available height of landing doors.This document is not applicable to lifts installed before the date of its publication.