NBN EN 50209:1998

Test of insulation of bars and coils of high-voltage machines

ACTIVE

About this standard

Languages
English and French
Type
NBN Electro
Status
ACTIVE
Publication date
25 May 1998
Replaces
HD 345 S1:1976
ICS Code
29.080 (Insulation)
29.160.10 (Components for rotating machines)
Withdrawn Date
Price
€ 58,00

Summary

This specification applies to rotating electrical machines with rated voltages (Un) from 5 kV to 24 kV inclusive and with rated output from 5 MVA upwards and from 5 MW upwards for motors Requirements for machines with rated voltage above 24 kV should remain the subject of individual agreement This specification is also applicable to machines with rated outputs between 1MVA( 1MW) and 5 MVA(5MW) and with rated voltages of 5 kV and above, provided its use has been agreed beforehand In the case of machines whose windings are cured in the stator, tests on the separate winding elements are not possible for these machines the requirements in Part B apply. The test of the conductor lamination insulation must however be carried out in accordance with 23 of Part A of this standard