Multiple split-system air conditioners and air-to-air heat pumps — Testing and rating for performance (ISO 15042:2017)
This document specifies the performance testing, the standard conditions and the test methods fordetermining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.This document is applicable to the following equipment:― basic multi-split systems, modular multi-split systems and modular heat recovery multi-splitsystems. These multi-split systems include air-to-air systems with non-ducted and/ or ductedindoor units with integral fans and indoor units supplied without fans.This document is limited to:― residential, commercial and industrial split-system air conditioners and heat pumps ― factory-made, electrically driven and use mechanical compression ― single- and multiple-circuit split-systems which utilize one or more compressors with no morethan two steps of control of the outdoor unit or― split-systems with a single refrigeration circuit which utilize one or more variable-speedcompressors or alternative compressor combinations for varying the capacity of the system bythree or more steps.These split-systems are designed to operate with a combination of one or more outdoor units andtwo or more indoor units designed for individual operation, and such modular systems are capable oftransferring recovered heat from one or more indoor units to other units in the same system.The requirements of testing and rating contained in this document are based on the use of matchedassemblies.This document is not applicable to the rating and testing of the following:a) water-cooled or water source equipment b) mobile (single-duct) units having a condenser exhaust duct c) individual assemblies not constituting a complete refrigeration system d) equipment using the absorption refrigeration cycle.e) ducted air conditioners and/ or ducted heat pumps, rated at less than 8 kW and intended to operateat external static pressures of less than 25 Pa, controlled by a single thermostat/ controller (refer toISO 5151) f) multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or moreindoor units, controlled by a single thermostat/ controller (refer to ISO 5151 or ISO 13253).© ISO 2017 – All rights reserved 1ISO 15042:2017(E)This document does not cover the determination of seasonal efficiencies or seasonal part-loadperformances, which can be required in some countries because they provide a better indication ofefficiency under actual operating conditions.NOTE Throughout this document, the terms “equipment” and “systems” mean “multi-split air conditioners”and/ or “multi-split heat pumps”.
View in